Digital Video
Digital Video Output connector
ASI In
75 Ohm BNC input.
ASI Out
75 Ohm BNC output.
RF 1, 2, 3 & 4
x4 L-Band inputs, 75 Ohm F-Connector (RD30-01-LB option)
GigE In/Out
x2 10/100/1000 GigE ports for UDP or RTP transport ingress/egress
Cooling
The RD-30 is cooled via forced induction through the front of the unit and exhausted through the vents in the rear of the
chassis. The RD-30 is equipped with a temperature controlled status indicator. If the temperature inside the unit exceeds 60° C
the red “Error” text will illuminate on the front panel and a description of the error will appear in the “Error List.”
Rack Information
The RD-30 is intended to be mounted in a standard 19” rack. It occupies 1RU of rack space and the connections are all on the
rear of the unit.