beautypg.com

Standard test conditions, Capacitance – Zilog Z8PE002 User Manual

Page 9

background image

Z8PE002

ZiLOG

Z8Plus OTP Microcontroller

DS008700-Z8X0799

P R E L I M I N A R Y

9

STANDARD TEST CONDITIONS

The characteristics listed below apply for standard test con-
ditions as noted. All voltages are referenced to Ground. Pos-
itive current flows into the referenced pin (Figure 7).

CAPACITANCE
T

A

= 25ºC, V

CC

= GND = 0V, f = 1.0 MHz, unmeasured pins returned to GND.

Figure 7. Test Load Diagram

From Output

Under Test

150 pF

Parameter

Min

Max

Input capacitance

0

12 pF

Output capacitance

0

12 pF

I/O capacitance

0

12 pF