Troubleshooting

Regarding the indicator lamps (continued)

POWER

indicator

LAMP

indicator

TEMP

indicator

Description

Blinking

In

Red

or

Lighting

In

Red

Turned

off

Blinking

In

Red

The cooling fan is not operating.

Please turn the power off, and allow the projector to

cool down at least 20 minutes. After the projector has

sufficiently cooled down, please make confirmation

that no foreign matter has become caught in the fan,

etc., and then turn the power on again.

If the same indication is displayed after the remedy,

please contact your dealer or service company.

Blinking

In

Red

or

Lighting

In

Red

Turned

off

Lighting

In

Red

There is a possibility that the interior portion

has become heated.

Please turn the power off, and allow the projector to

cool down at least 20 minutes. After the projector has

sufficiently cooled down, please make confirmation of

the following items, and then turn the power on again.

• Is there blockage of the air passage aperture?

• Is the air filter dirty?

• Please use the unit within the usage temperature

parameters (0°C to 35°C, 40°C or 45°C (

User's

Manual (concise))).

• Is the setting for ALTITUDE appropriate?

For details on ALTITUDE, refer to ALTITUDE

of SERVICE in the OPTION menu (69). If the

projector is used with a wrong setting, it may cause

damage to the projector itself or the parts inside.

Lighting

In

Green

Simultaneous

blinking in

Red

It is time to clean the air filter.

Please immediately turn the power off, and clean or

change the air filter referring to the section

Cleaning

and replacing the air filter. After cleaning or

changing the air filter, please be sure to reset the

filter timer. After the remedy, reset the power to ON.

Lighting

In

Green

Alternative

blinking in

Red

There is a possibility that the interior portion

has become overcooled.

Please use the unit within the usage temperature

parameters (0°C to 35°C, 40°C or 45°C (

User's

Manual (concise))). After the treatment, reset the

power to ON.

Blinking In

Green

for

approx. 3

seconds.

Turned

off

Turned

off

At least 1 Power ON schedule is saved to the

projector.

Please refer to

3.1.7 Schedule Settings in the

Network Guide.

(continued on next page)