Start-up Validation

When you switch power ON to the DEC3.3 controller (firmware 01.00.006 and up), the following

indications will confirm that the major system elements are working correctly:

BEEP! – a loud beep indicates that the processor has initialized and is functioning

correctly.

FANS – fans run for three seconds

HEATER – the heater turns on for 15 seconds. This is enough to get warm to the touch.

DMX Connections

DMX refers to USITT DMX512, a commonly used control protocol in the entertainment industry,

running over RS485. Consult USITT DMX installation guidelines when laying out a system, or

employ a qualified DMX system integrator.

A DMX network will be required if:

a) The projector inside the enclosure requires a DMX control signal

b) You wish to monitor the enclosure using RDM

c) You wish to control the enclosure lamp relay over DMX

DMX Terminations

Note: DMX will not normally be used in projector installations.

Pinout: (1) Ground, (2) Data -, (3) Data +.

DMX Connectors:

1

DMX IN from network

2

DMX OUT to projector (or to network

if not controlling projector)

3

DMX IN from projector

4

DMX OUT to network

Note: If the enclosed equipment does not

use DMX, then connector (2) on the

controller is DMX OUT for the enclosure.

DMX Line Terminations

DMX cable runs must be terminated at

the far end of the cable run with a

DMX IN from

outside world

DMX OUT to

next DMX device

❹ ❸ ❷ ❶

DMX terminal Pinout Detail