Start-up Validation
When you switch power ON to the DEC3.3 controller (firmware 01.00.006 and up), the following
indications will confirm that the major system elements are working correctly:
BEEP! – a loud beep indicates that the processor has initialized and is functioning
correctly.
FANS – fans run for three seconds
HEATER – the heater turns on for 15 seconds. This is enough to get warm to the touch.
DMX Connections
DMX refers to USITT DMX512, a commonly used control protocol in the entertainment industry,
running over RS485. Consult USITT DMX installation guidelines when laying out a system, or
employ a qualified DMX system integrator.
A DMX network will be required if:
a) The projector inside the enclosure requires a DMX control signal
b) You wish to monitor the enclosure using RDM
c) You wish to control the enclosure lamp relay over DMX
DMX Terminations
Note: DMX will not normally be used in projector installations.
Pinout: (1) Ground, (2) Data -, (3) Data +.
DMX Connectors:
1
DMX IN from network
2
DMX OUT to projector (or to network
if not controlling projector)
3
DMX IN from projector
4
DMX OUT to network
Note: If the enclosed equipment does not
use DMX, then connector (2) on the
controller is DMX OUT for the enclosure.
DMX Line Terminations
DMX cable runs must be terminated at
the far end of the cable run with a
DMX IN from
outside world
DMX OUT to
next DMX device
❹ ❸ ❷ ❶
DMX terminal Pinout Detail