beautypg.com

Single feed operation (factory default), Split feed operation – Tempest Cyclone User Manual

Page 18

background image



Cyclone Enclosure User Manual

page 18

Single Feed Operation (factory default)

Enclosure and projector share the same electrical circuit.

Circuit must be powered ON 24/7.

Connect incoming power to the terminals labeled MAINS:

(E) Earth/Ground

(L) Live

(N) Neutral

E L N

Split Feed Operation

Enclosure and projector have separate electrical feeds.

The enclosure circuit must be powered ON 24/7.

When splitting the feeders, both circuits should be on the same phase and at the same supply

voltage.

1 Use a wire cutter to cut the copper links on the

DEC3.2 board in four places.

2 Connect incoming ENCLOSURE power to the

terminals labeled MAINS. This supply MUST be

maintained 24/7.

(E) Earth/Ground (L) Live

(N) Neutral

3 Connect incoming PROJECTOR power to the

terminals labeled SPLIT:

(E) Earth/Ground (L) Live

(N) Neutral

Projector Supply

(split mode)

Enclosure Supply
(100-250VAC 50/60Hz)

Fan 1

Fan 2

Heater(s)

Projector

receptacle

Cut here for split

supply operation

Projector Supply

(split mode)

Enclosure Supply
(100-250VAC 50/60Hz)

Fan 1

Fan 2

Heater(s)

Projector

receptacle

Cut here for split

supply operation

E L N

Projector

Power

E L N

Enclosure

Power

1

This manual is related to the following products: