Wiring, 3 wiring – Tempest Cyclone User Manual
Page 16

Cyclone Enclosure User Manual
page 16
3 Wiring
All electrical work must be carried out by a properly licensed electrician, in compliance
with local electrical standards. Failure to observe this point will void the factory warranty
for the Tempest Enclosure.
1
Switch off power to the branch circuit, carefully following lockout and tag-out procedures.
Failure to do so could cause serious injury or death.
2
You will need two electrical junction boxes, located within a short distance from the enclosure,
one for power, one for signal (usually CAT5). Use outdoor-rated flexible conduit between the
box and the enclosure, to allow for the back door to open.
3
AC and signal circuits must be wired in separate conduits.
Conduit Entry Holes – 8400 Model (for Christie Roadie)
The smaller conduit entry holes (A) accept US ½”
conduit fittings, and international 20-22mm (OD)
conduit fittings.
The larger entry holes (B) accept 2”/50mm OD fittings
for signal cables with larger molded connectors.
The CamLok Connectors (C) are for the DC ballast
cables.
AC
Power
Signal
Flexible Conduit
208VAC
or
230VAC
Picture
Source
A A B B C C
Conduit Entry Holes
1 .875”/22.2mm for AC
power
2 .875”/22.2mm for Data
(CAT5 or fiber)
3 2”/50.8mm for pre-wired
signal cables with large
connectors.
Conduit Entries may be fitted
with flexible conduit fittings
or cable glands (not included)