Cyclone hush remote fan plate – Tempest Cyclone User Manual
Page 15

Cyclone Enclosure User Manual
page 15
Cyclone HUSH Remote Fan Plate
1. Install the Remote fan plate at the end of the exhaust duct, with the airflow direction
AWAY from the Cyclone enclosure. See illustration on p12
2. Connect a 3-conductor wire rated at 10 Amps, 250 Volts to the terminals on the Remote
Fan Plate.
3. Pull the Fan wire through the duct to the Digital Enclosure Control (DEC) controller in the
Cyclone enclosure.
4. Terminate the fan wire to the DEC FAN 1 and Earth (Ground) Terminals as shown here:
Projector Supply
(split mode)
Enclosure Supply
(100-250VAC 50/60Hz)
Fan 1
Fan 2
Heater(s)
Projector
receptacle
Cut here for split
supply operation
Remote 4-Fan Plate
Cyclone 8102
Cyclone 8200 and up
Remote 2-Fan Plate
Cyclone 8000, 8100 Series
Fan Wire (European color