beautypg.com

Cyclone hush remote fan plate – Tempest Cyclone User Manual

Page 15

background image



Cyclone Enclosure User Manual

page 15

Cyclone HUSH Remote Fan Plate





1. Install the Remote fan plate at the end of the exhaust duct, with the airflow direction

AWAY from the Cyclone enclosure. See illustration on p12

2. Connect a 3-conductor wire rated at 10 Amps, 250 Volts to the terminals on the Remote

Fan Plate.

3. Pull the Fan wire through the duct to the Digital Enclosure Control (DEC) controller in the

Cyclone enclosure.

4. Terminate the fan wire to the DEC FAN 1 and Earth (Ground) Terminals as shown here:

Projector Supply

(split mode)

Enclosure Supply
(100-250VAC 50/60Hz)

Fan 1

Fan 2

Heater(s)

Projector

receptacle

Cut here for split

supply operation

Remote 4-Fan Plate
Cyclone 8102
Cyclone 8200 and up

Remote 2-Fan Plate
Cyclone 8000, 8100 Series

Fan Wire (European color

codes shown here)

This manual is related to the following products: