beautypg.com

Other bios error messages – Dell 3 User Manual

Page 210

background image

208

Troubleshooting

w

w

w

.d

e

ll

.co

m

|

s

u

p

p

o

rt

.d

e

ll.c

o

m

Other BIOS Error Messages

Table 13-3 explains the other BIOS error messages that can display.

Ta b l e 1 3 - 3 . O t h e r B I O S E r r o r M e s s a g e s

Message

Problem

Suggested Solution

Following
SCSI disk not
found and no
empty slot
available for
mapping it

The physical disk roaming

feature did not find the

physical disk with the

displayed SCSI ID. No

slot is available to map the

physical drive. PERC 3

cannot resolve the

physical drives into the

current configuration.

Reconfigure the array.

Following
SCSI IDs have
the same data
y, z

Channel x: a,
b, c

The physical drive

roaming feature found the

same data on two or more

physical drives on channel

x with SCSI IDs a, b, and

c. PERC 3 cannot

determine the drive that

has the duplicate

information.

Remove the drive or drives

that should not be used.

Unresolved
configuration
mismatch
between disks
and NVRAM on
the adapter

The PERC 3 is unable to

determine the proper

configuration after

reading both NVRAM and

Configuration on Disk.

Press to run

the BIOS Configuration

Utility. Choose

Configure

—>

New

Configuration to create a

new configuration.
CAUTION: This will delete

any existing configuration.