Perform the following steps to connect SCSI devices:

1

Disable termination on any SCSI device that does not sit at the end of

the SCSI bus.

2

Configure all SCSI devices to supply termination power (TermPWR.)

3

Set proper target IDs (TIDs) for all SCSI devices.

Cable Suggestions

System throughput problems can occur if SCSI cable use is not maximized.
You should:

• Use cables up to 12 meters for LVD devices.
• For single-ended SCSI devices, use the shortest SCSI cables (no more

than 3 meters for Fast SCSI, no more than 1.5 meters for an 8-drive

Ultra SCSI system, and no more than 3 meters for a 6-drive Ultra SCSI

system.)

• Use active termination.
• Avoid clustering the cable nodes.
• Note that cable stub length should be no more than 0.1 meter (4

inches.)

• Route SCSI cables carefully.
• Use high impedance cables.
• Do not mix cable types. (Choose either flat or rounded and shielded or

non-shielded.)

• Note that ribbon cables have fairly good cross-talk rejection

characteristics.

Step 7—Set Target IDs

Set target identifiers (TIDs) on the SCSI devices. Each device in a specific
SCSI channel must have a unique TID in that channel. Non-disk devices
(CD or tapes) should have unique SCSI IDs regardless of the channel where
they are connected
. See the documentation for each SCSI device to set the
TIDs.