Naming Units and Channels

Connected units are displayed in the top pane in alphabetical order. Use names with
number prefixes if you wish to display them in your own order.

To name a unit and its channels:

1. Select a unit in the top pane.

2. Select the yellow text in the right pane (under the Dugan logo) and type a name.

3. Press the Enter key on the keyboard to set the name.

4. To name a channel, select the yellow text and type a name.

5. Press the Enter key on the keyboard to set the name.

Channel naming is cleared by pressing

reset

(see page 48).

Channel Pane

The Channel Pane contains the controls and indicators for each channel. Channels
are always in one of three modes:

man

,

auto

, or

mute

. The active channel mode illu-

minates. All transitions are made with a smooth, rapid fade. Select a channel mode
by pressing the individual mode buttons or the Master

PRESET

button.

Figure 5-3 shows a typical system: channels 1–4 in

auto

with ambient noise

,

and chan-

nels 5–8 in

mute

.

Figure 5-3 Channel Pane