10 stealth mode, Ditto**** initializing... preparing factory reset – CRU Ditto Forensic FieldStation User Manual
Page 28

28
Protecting Your Digital Assets
TM
Ditto Forensic FieldStation User Manual
9.3 DISK INFO
The “Disk Info” screen shows all available disks attached to either the source or desti-
nation ports. Ports are shown only if a disk is connected there. Press
Enter
(View) and
then
Up
or
Down
to scroll through the following information about each connected disk:
•
Model number
•
Disk capacity
•
File system
9.4 PERFORM ACTION
After you adjust settings to your specifications, you are ready to put the Ditto Forensic FieldStation to work.
The “Perform Action” screen lets you start or abort any of the Ditto Forensic FieldStation’s actions using the
current settings.
j. On the “Perform Action” screen, use the
Up
and
Down
buttons to cycle through the available actions.
Press
Enter
to select the one you want.
k. Cycle through the available settings for the action. Press
Enter
if you wish to modify them.
l. When you are finished modifying settings, scroll down to option that asks you to start the action (ex.
“Start Physical Image?”. Press
Enter
to begin.
The status and remaining time will be displayed on the LCD screen as the Ditto Forensic FieldStation per-
forms the action. To abort an action, press the
Back
button. The LCD screen will ask if you wish to abort the
action. Press
Enter
to confirm, or
Back
to cancel the abort request.
9.5 FACTORY RESET
To reset the Ditto Forensic FieldStation’s settings back to their factory defaults, press
and hold the
Up
,
Enter
, and
Down
navigation buttons while powering the unit on. The
Ditto Forensic FieldStation will start up and then display the text, “Preparing Factory
Reset” (see Figure 27).
You will then be prompted to confirm your choice to reset the Ditto. Press
Enter
to
continue or
Back
to cancel.
You can also use the browser interface to perform a factory reset. See Section 8.1.3.
10 STEALTH MODE
Stealth Mode turns off all LEDs and LCDs on the Ditto Forensic FieldStation. You can enable Stealth Mode by
flipping the physical “Stealth Mode” switch on the Destination Outputs side of the Ditto Forensic FieldStation
(see Section 1.2).
You can also enable it from the browser interface. Click on the
Configure tab
, and then under the “System” tab
change the “Stealth Mode” drop-down box to “Enabled.” Then click
Commit Changes
.
If Stealth Mode is enabled from the browser interface, the physical switch cannot override it.
****DITTO****
Initializing...
Preparing Factory Reset
Figure 27.
The “Preparing Factory Reset” screen on
the Front Panel LCD.
Source eSATA:
HTS5410806XXXXX
79.8GB
No file system
Figure 26.
The “Disk Info” screen on the Front Panel
LCD.
NOTE