beautypg.com

10 stealth mode, Ditto**** initializing... preparing factory reset – CRU Ditto Forensic FieldStation User Manual

Page 28

background image

28

Protecting Your Digital Assets

TM

Ditto Forensic FieldStation User Manual

9.3 DISK INFO

The “Disk Info” screen shows all available disks attached to either the source or desti-
nation ports. Ports are shown only if a disk is connected there. Press

Enter

(View) and

then

Up

or

Down

to scroll through the following information about each connected disk:

Model number

Disk capacity

File system

9.4 PERFORM ACTION

After you adjust settings to your specifications, you are ready to put the Ditto Forensic FieldStation to work.
The “Perform Action” screen lets you start or abort any of the Ditto Forensic FieldStation’s actions using the
current settings.

j. On the “Perform Action” screen, use the

Up

and

Down

buttons to cycle through the available actions.

Press

Enter

to select the one you want.

k. Cycle through the available settings for the action. Press

Enter

if you wish to modify them.

l. When you are finished modifying settings, scroll down to option that asks you to start the action (ex.

“Start Physical Image?”. Press

Enter

to begin.

The status and remaining time will be displayed on the LCD screen as the Ditto Forensic FieldStation per-
forms the action. To abort an action, press the

Back

button. The LCD screen will ask if you wish to abort the

action. Press

Enter

to confirm, or

Back

to cancel the abort request.

9.5 FACTORY RESET

To reset the Ditto Forensic FieldStation’s settings back to their factory defaults, press
and hold the

Up

,

Enter

, and

Down

navigation buttons while powering the unit on. The

Ditto Forensic FieldStation will start up and then display the text, “Preparing Factory
Reset” (see Figure 27).

You will then be prompted to confirm your choice to reset the Ditto. Press

Enter

to

continue or

Back

to cancel.

You can also use the browser interface to perform a factory reset. See Section 8.1.3.

10 STEALTH MODE

Stealth Mode turns off all LEDs and LCDs on the Ditto Forensic FieldStation. You can enable Stealth Mode by
flipping the physical “Stealth Mode” switch on the Destination Outputs side of the Ditto Forensic FieldStation
(see Section 1.2).

You can also enable it from the browser interface. Click on the

Configure tab

, and then under the “System” tab

change the “Stealth Mode” drop-down box to “Enabled.” Then click

Commit Changes

.

If Stealth Mode is enabled from the browser interface, the physical switch cannot override it.

****DITTO****

Initializing...

Preparing Factory Reset

Figure 27.

The “Preparing Factory Reset” screen on

the Front Panel LCD.

Source eSATA:

HTS5410806XXXXX

79.8GB
No file system

Figure 26.

The “Disk Info” screen on the Front Panel

LCD.

NOTE