Communications, Configuration, Site – CIRCUTOR CDP-0 User Manual
Page 46: Via web

CDP
46
Instruction Manual
6.- COMMUNICATIONS
The unit has two web sites:
Configuration web site.
Display web site.
6.1. CONFIGURATION WEB SITE
The CDP can be used to configure the parameters of the
Table 15
, via Web.
Table 15: Configuration parameters.
Description
Units
Default
value
Inverter type
-
Fronius
Inverter power
W
1
Number of inverters
-
1
Work mode configuration
-
Single-phase
Activate compensation
-
0
No injection threshold
%
3
Permitted power to be injected
%
0
Activate the management of non-critical loads
-
disabled
Maximum modulation value
%
50
Relay connection order
-
Priority
Maximum grid contribution value
%
25
Minimum reconnection time
Minutes
5
Power to be consumed by each of the loads connected
to the relays
W
-
Minimum time that the load must stay connected
Minutes
15
Activate reverse current relay
-
1
Grid injection validation time
Seconds
0
Reconnection time
Seconds
0
Maximum number of reconnections
-
0
Reconnection period
Seconds
0
Time between datalogger logs
Minutes
15
Activate external unit to measure the user's current
-
0
Transformation ratio for the current of L1 (Channel for
measuring the user's current in single-phase mode)
A/250 mA
1
Peripheral number address
(External unit activated)
-
-
Transformation ratio for the current of L2 (Channel for
measuring the grid's current in single-phase mode)
A/250 mA
1
Peripheral number address
-
1
Activate external unit to measure the inverter's current
-
0
Transformation ratio for the current of L3 (Channel for
measuring the inverter's current in single-phase mode)
A/250 mA
1
Peripheral number address (External unit activated)
-
2
Communication speed with the grid analyzers.
Bauds
19200