Report worksheet, Static power and dynamic current per voltage rail, Power up current – Altera PowerPlay Early Power Estimator User Manual
Page 49: Report worksheet -39, Power up current -39

Module
Parameters
Description
SDRAM
Frequency
Enter the operating frequency of the selected DDR protocol
used.
Type
Select the DDR protocol used.
Data Width
Select the width of the data lines (in bits).
Peripherals
Usage
Select On for module in use. Turn on the appropriate voltage for
one of the I/O banks before selecting the module.
Voltage
Select the voltage used for this module.
Report Worksheet
The Report worksheet shows all the information and power estimation results from the PowerPlay EPE
spreadsheet. You can find the power supply recommendations in the Power Supply Current (A) section,
which describes all the power supply requirements for the device that your design uses in the Min Current
Requirement (A) and the User Mode Current Requirement (A) columns.
The Min Current Requirement (A) column is not available for MAX 10 devices.
Static Power and Dynamic Current per Voltage Rail
The Report worksheet shows all the information and power estimation results from the PowerPlay EPE
spreadsheet. You can find the power supply recommendations in the Power Supply Current (A) section,
which describes all the power supply requirements for the device that your design uses in the Min Current
Requirement (A) and the User Mode Current Requirement (A) columns.
Figure 3-27: Separate Static and Dynamic Current in Power Supply Current Section
Power Up Current
In some device families, the power up current can be larger than the dynamic current required in the I/O
worksheet. For example, in Stratix III and Stratix IV devices, the I
CCPD
value on the I/O worksheet is
different than the Minimum current requirement for I
CCPD
in Report worksheet.
Altera provides the minimum current required for the V
CCPD
power rail for each voltage supply used, but
is not dependent on how many banks use that voltage supply.
To estimate the power up current, use the Report worksheet and compare the minimum current require‐
ment with user mode current requirement.
UG-01070
2015.01.20
Report Worksheet
3-39
PowerPlay Early Power Estimator Worksheets