Operating conditions, Operating conditions –4 – Altera EthernetBlaster II User Manual
Page 28

3–4
Chapter 3: EthernetBlaster II Communications Cable Specifications
Operating Conditions
EthernetBlaster II Communications Cable User Guide
January 2014
Altera Corporation
Operating Conditions
Table 3–3
through
Table 3–5
list the maximum ratings, recommended operating
conditions, and DC operating conditions for the EthernetBlaster II communication
cable.
Table 3–3
lists the EthernetBlaster II cable absolute maximum ratings.
lists the EthernetBlaster II Cable recommended operating conditions.
Table 3–5
lists the EthernetBlaster II Cable DC operating conditions.
Table 3–3. EthernetBlaster II Cable Absolute Maximum Ratings
Symbol
Parameter
Conditions
Min
Max
Unit
V
CC(TARGET)
Target supply voltage
With respect to ground
–0.3
5.5
V
V
CC(SYS)
System supply voltage
With respect to ground
—
36.0
V
I
I
Input current
TDO
or
dataout
–10.0
10.0
mA
I
o
Output current
TCK
,
TMS
,
TDI
,
nCS
,
nCE
–10.0
10.0
mA
Table 3–4. EthernetBlaster II Cable Recommended Operating Conditions
Symbol
Parameter
Conditions
Min
Max
Unit
V
CC(TARGET)
Target supply voltage, 3.3-V operation
—
3.0
3.6
V
Target supply voltage, 2.5-V operation
—
2.375
2.625
V
Target supply voltage, 1.8-V operation
—
1.71
1.89
V
Target supply voltage, 1.5-V operation
—
1.43
1.57
V
Target supply voltage, 1.2-V operation
—
1.1
1.26
V
Table 3–5. EthernetBlaster II Cable DC Operating Conditions
(Part 1 of 2)
Symbol
Parameter
Conditions
Min
Max
Unit
V
IH
High-level input voltage
V
CC(TARGET)
= 3.3 V
2.0
—
V
High-level input voltage
V
CC(TARGET)
= 2.5 V
1.6
—
V
High-level input voltage
V
CC(TARGET)
= 1.8 V
0.65 * V
CC(TARGET)
—
V
High-level input voltage
V
CC(TARGET)
= 1.5 V
0.65 * V
CC(TARGET)
—
V
High-level input voltage
V
CC(TARGET)
= 1.2 V
0.9 * V
CC(TARGET)
—
V
V
IL
Low-level input voltage
V
CC(TARGET)
= 3.3 V
—
0.8
V
Low-level input voltage
V
CC(TARGET)
= 2.5 V
—
0.7
V
Low-level input voltage
V
CC(TARGET)
= 1.8 V
—
0.35 * V
CC(TARGET)
V
Low-level input voltage
V
CC(TARGET)
= 1.5 V
—
0.35 * V
CC(TARGET)
V
Low-level input voltage
V
CC(TARGET)
= 1.2 V
—
0.1 * V
CC(TARGET)
V
V
OH
3.3-V high-level output voltage
V
CC(TARGET)
= 3.0 V, IOH = 20 mA
V
CC(TARGET)
– 0.4
—
V
2.5-V high-level output voltage
V
CC(TARGET)
= 2.375 V, IOH = 20 mA
V
CC(TARGET)
– 0.4
—
V
1.8-V high-level output voltage
V
CC(TARGET)
= 1.71 V, IOH = 20 mA
V
CC(TARGET)
– 0.4
—
V
1.5-V high-level output voltage
V
CC(TARGET)
= 1.43 V, IOH = 20 mA
V
CC(TARGET)
– 0.4
—
V
1.2-V high-level output voltage
V
CC(TARGET)
= 1.14 V, IOH = 20 mA
V
CC(TARGET)
– 0.4
—
V