Restoring the max v cpld to the factory settings – Altera DSP Development Kit, Stratix V Edition User Manual
Page 55
Appendix A: Programming the Flash Memory Device
A–5
Restoring the MAX V CPLD to the Factory Settings
July 2013
Altera Corporation
DSP Development Kit, Stratix V Edition
User Guide
13. The restore script cannot restore the board’s MAC address automatically. In the
Nios II command shell, type the following Nios II EDS command:
nios2-terminal
r
and follow the instructions in the terminal window to generate a unique MAC
address.
f
To ensure that you have the most up-to-date factory restore files and information
about this product, re
Altera website.
Restoring the MAX V CPLD to the Factory Settings
This section describes how to restore the original factory contents to the MAX V
CPLD on the development board. Make sure you have the Nios II EDS installed, and
perform the following instructions:
1. Set the board switches to the factory default settings described in
1
DIP switch SW3.1 set to on includes the MAX V device in the JTAG chain.
2. Launch the Quartus II Programmer.
3. Click Auto Detect.
4. Click Add File and select
dir>\kits\stratixVGS_5sgsmd5kf40_dsp\factory_recovery\max5.pof.
5. Turn on the Program/Configure option for the added file.
6. Click Start to download the selected configuration file to the MAX V CPLD.
Configuration is complete when the progress bar reaches 100%.
f
To ensure that you have the most up-to-date factory restore files and information
about this product, re
Altera website.