6–14

Chapter 6: Board Test System

Using the Board Test System

DSP Development Kit, Stratix V Edition

July 2013

Altera Corporation

User Guide

Pattern sync

—Shows the pattern synced or not synced state. The pattern is

considered synced when the start of the data sequence is detected after channel
lock is acquired.

Port

The Port control allows you to specify which interface to test. The following port tests
are available:

SDI

(2.97 Gbps)

HSMA Transceivers x8

(10 Gbps+)

HSMA x3 CMOS

HSMA x17 LVDS

PMA Setting

The PMA Setting

button allows you to make changes to the PMA parameters that

affect the active transceiver interface. The following settings are available for analysis:

Serial Loopback

—Routes signals between the transmitter and the receiver. Enter

the following values to enable the serial loopbacks:

0

= High speed serial transceiver signals to loopback on the board

1

= Serial loopback (internal loopback)

2

= Reverse serial loopback pre-CDR

4

= Reverse serial loopback post-CDR

VOD

—Specifies the voltage output differential of the transmitter buffer.

Pre-emphasis tap

Pre

—Specifies the amount of pre-emphasis on the pre-tap of the transmitter

buffer.

First post

—Specifies the amount of pre-emphasis on the first post tap of the

transmitter buffer.

Second post

—Specifies the amount of pre-emphasis on the second post tap of

the transmitter buffer.

Equalizer

—Specifies the setting for the receiver equalizer.

DC gain

—Specifies the DC portion of the receiver equalizer.

Data Type

The Data type control specifies the type of data contained in the transactions. The
following data types are available for analysis:

PRBS 7

—Selects pseudo-random 7-bit sequences.

PRBS 15

—Selects pseudo-random 15-bit sequences.

PRBS 23

—Selects pseudo-random 23-bit sequences.

PRBS 31

—Selects pseudo-random 31-bit sequences.

HF—

Selects highest frequency divide-by-2 data pattern "10101010"

HF1—

Selects next highest frequency divide-by-6 data pattern "111000111000"