Chapter 6: Board Test System

The Power Monitor

DSP Development Kit, Stratix V Edition

July 2013

Altera Corporation

User Guide

The Power Monitor communicates with the MAX V device on the board through the
JTAG bus. A power monitor circuit attached to the MAX V device allows you to
measure the power that the Stratix V GS FPGA device is consuming regardless of the
design currently running.

Figure 6–10

shows the Power Monitor.

The following sections describe the Power Monitor controls.

General Information

The General information controls display the following information about the
MAX V device:

MAX V version

—Indicates the version of MAX V code currently running on the

board. The MAX V code resides in the dir>\kits\stratixVGS_5sgsmd5kf40_dsp\factory_recovery and dir>\kits\stratixVGS_5sgsmd5kf40_dsp\examples\max5 directories. Newer
revisions of this code might be available on the

DSP Development Kit, Stratix V

Edition

page of the Altera website.

Power rail

—Selects the power rail to measure. After setting the Power rail list to

the desired rail, click Reset to refresh the screen with new board readings.

1

All rails use a 0.003 ohm resistor, except S5_VCCINT that uses 0.001 ohms.

Figure 6–10. The Power Monitor