Restoring the max ii cpld to the factory settings – Altera Arria V GX FPGA User Manual
Page 57

Appendix A: Programming the Flash Memory Device
A–5
Restoring the MAX II CPLD to the Factory Settings
July 2012
Altera Corporation
Arria V GX FPGA Development Kit
User Guide
Restoring the MAX II CPLD to the Factory Settings
This section describes how to restore the original factory contents to the MAX II CPLD
on the FPGA development board. Make sure you have the Nios II EDS installed, and
perform the following instructions:
1. Set the board switches to the factory default settings described in
Switch and Jumper Settings” on page 4–2
.
2. Launch the Quartus II Programmer.
3. Click Auto Detect.
4. Click Add File and select
dir>\kits\arriaVGX_5agxfb3hf40es_fpga\factory_recovery\max2.pof.
5. Turn on the Program/Configure option for the added file.
6. Click Start to download the selected configuration file to the MAX II CPLD.
Configuration is complete when the progress bar reaches 100%.
f
To ensure that you have the most up-to-date factory restore files and information
about this product, re
page of the Altera
website.