Pssu assignment in system environment b, 4function description, 2 configuration – Pilz PSSu E S ABS SSI User Manual

Page 21

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-5

4.2

Configuration

4

Function description

4.2.2.2

PSSu assignment in system environment B

PSSu assignment in system environment B

4-

][Funktionsbeschreibung_BA_Ein/Ausgabe ST-ABS Sys B

Data access is via pre-defined I/O data types:

(1)

"Counter input passive" indicates that the module is not receiving any

values from the absolute encoder. Possible causes:

Open circuit

Absolute encoder is not connected.

I/O data name

I/O data type

I/O data element

Key

InputData

ST_I_ABS_SSI

Data: DWORD

Current position data

InputError: BOOL

FALSE: Counter input active
TRUE: Counter input passive

(1)

DataFrameError: BOOL

FALSE: No error within the data frame
TRUE: Data frame is faulty

ModuleError: BOOL

FALSE: No error within the module
TRUE: Module is faulty