Pssu assignment in system environment b, 4function description, 2 configuration – Pilz PSSu E S ABS SSI User Manual
Page 21

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-5
4.2
Configuration
4
Function description
4.2.2.2
PSSu assignment in system environment B
PSSu assignment in system environment B
4-
][Funktionsbeschreibung_BA_Ein/Ausgabe ST-ABS Sys B
Data access is via pre-defined I/O data types:
(1)
"Counter input passive" indicates that the module is not receiving any
values from the absolute encoder. Possible causes:
Open circuit
Absolute encoder is not connected.
I/O data name
I/O data type
I/O data element
Key
InputData
ST_I_ABS_SSI
Data: DWORD
Current position data
InputError: BOOL
FALSE: Counter input active
TRUE: Counter input passive
(1)
DataFrameError: BOOL
FALSE: No error within the data frame
TRUE: Data frame is faulty
ModuleError: BOOL
FALSE: No error within the module
TRUE: Module is faulty