3 safety, 1 intended use, Section 3 – Pilz PSSu K S 16DO 0.5 User Manual
Page 9: Safety, Intended use, 3safety

Safety
Operating Manual PSSu K S 16DO 0.5
22059EN07
9
3
Safety
3.1
Intended use
The module provides type 1 outputs in accordance with IEC 611312. It may be used to
switch:
}
Resistive loads
}
Inductive loads
}
Capacitive loads
The module PSSu K S 16DO 0.5 may be used as a safety component in accordance with
the Lifts Directive 95/16/EC, EN 811, EN 812 and EN 1151.
The programmable safety system should be installed in a protected environment that meets
at least the requirements of pollution degree 2. Example: Protected inside space or control
cabinet with protection class IP54 and corresponding air conditioning.
Intended use includes making the electrical installation EMCcompliant. Please refer to the
guidelines stated in the "PSSuniversal Installation Manual". The module is designed for use
in an industrial environment. It is not suitable for use in a domestic environment, as this can
lead to interference.
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the module
}
Use of the module outside the areas described in this manual
}
Any use of the module that is not in accordance with the technical details.
INFORMATION
The module is supported by:
}
PSSuniversal Configurator and PSSuniversal Assistant from Version
1.8.1.
}
PAS4000 from version 1.7.0
– We recommend that you always use the latest version (download
from www.pilz.de).
The PSSu K S 16DO 0.5 module may be used with the following connectors with spring
loaded terminals:
}
PSSu A Con 1/10 C
}
PSSu A Con 3/30 C
WARNING!
The module may not be used in combination with PSSu E F BSW(T) mod
ules in safetyrelated applications.