beautypg.com

7 operation, 1 messages, Section 7 – Pilz PNOZ m EF 4DI4DOR User Manual

Page 14: Operation, Messages, 7operation

background image

Operation

Operating Manual PNOZ m EF 4DI4DOR
1002702­EN­02

14

7

Operation

When the supply voltage is switched on, the PNOZmulti safety system copies the configur­
ation from the chip card.

The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up on the base unit.

The PNOZmulti control system is ready for operation when the "POWER" and "RUN" LEDs
on the base unit are lit continuously.

7.1

Messages

Legend:

LED on

LED flashes

LED off

LED

Error

PO
WE
R

Ru
n

Dia
g

Fa
ult

IFa
ult

OF
ault

No supply voltage

Expansion module PNOZ m EF 4DI4DOR running without
error

Expansion module PNOZ m EF 4DI4DOR is in a STOP
condition

Internal error on the expansion module PNOZ m EF
4DI4DORor on the overall system. Expansion module is in
a safe condition.

External error on the expansion module PNOZ m EF
4DI4DORor on the overall system. Expansion module is in
a safe condition.

Internal error on the inputs of the expansion module PNOZ
m EF 4DI4DOR. Expansion module is in a safe condition,
e.g. pulse error.

Internal error on the outputs of the expansion module
PNOZ m EF 4DI4DOR. Expansion module is in a safe
condition.

External error on the inputs of the expansion module
PNOZ m EF 4DI4DOR. Expansion module is in a safe
condition.

External error on the outputs of the expansion module
PNOZ m EF 4DI4DOR. Expansion module is in a safe
condition, e.g. defective feedback loop