Operation

Operating Manual PNOZ m EF 1MM
1003108­EN­01

20

7

Operation

When the supply voltage is switched on, the PNOZmulti safety system copies the configur­
ation from the chip card.

The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up on the base unit.

The PNOZmulti control system is ready for operation when the "POWER" and "RUN" LEDs
on the base unit are lit continuously.

7.1

Messages

Legend:

LED on

LED flashes

LED off

LED

Fault

Power

Run

Diag

Fault

Axis 1

No supply voltage

Expansion module PNOZ m EF 1MM running without er­
ror.

Expansion module PNOZ m EF 1MM is in a STOP con­
dition.

Internal error on the expansion module PNOZ m EF
1MM or on the overall system. Expansion module is in a
safe condition.

External error on the expansion module PNOZ m EF
1MM or on the overall system. Expansion module is in a
safe condition.

Internal error on axis 1 of the expansion module PNOZ
m EF 1MM. Expansion module is in a safe condition.

Implausible sensor signal.