beautypg.com

4 function description, 1 operation, 2 block diagram – Pilz PNOZ m EF 1MM User Manual

Page 10: 3 monitoring functions, Section 4, Function description, Operation, Block diagram, Monitoring functions, 4function description

background image

Function description

Operating Manual PNOZ m EF 1MM
1003108­EN­01

10

4

Function description

4.1

Operation

The motion monitoring module PNOZ m EF 1MM can monitor one axis. The motion monit­
oring module signals the status of the monitored values to the base unit. Depending on the
implemented safety circuit, the values may be transferred from the base unit to an output
on the control system, for example. Proximity switches are used to record the values.

The configuration of the motion monitoring module is described in detail in the PNOZmulti
Configurator's online help.

The relay conforms to the following safety criteria:

}

The circuit is redundant with built­in self­monitoring.

}

The safety function remains effective in the case of a component failure.

4.2

Block diagram

X4

A12 B12 S12 GND

X12

Mini-IO

4.3

Monitoring functions

Safe speed monitoring

The "Safe speed monitoring" function (SSM) monitors whether the current speed exceeds a
limit value.

If the configured limit value is exceeded, the output switches off. As soon as the value falls
below the limit value (plus hysteresis), the output switches off again.

8 limit values can be configured per axis in the PNOZmulti Configurator.

A tolerance range may also be set for the limit values used to monitor the speed. This toler­
ance range modifies the set limit values. As a result, one­off or periodic overshoots that ex­
ceed the limit values can be tolerated. 
The following values can be configured for the tolerance range: