4 function description, 1 operation, 2 block diagram – Pilz PNOZ m EF 1MM User Manual
Page 10: 3 monitoring functions, Section 4, Function description, Operation, Block diagram, Monitoring functions, 4function description

Function description
Operating Manual PNOZ m EF 1MM
1003108EN01
10
4
Function description
4.1
Operation
The motion monitoring module PNOZ m EF 1MM can monitor one axis. The motion monit
oring module signals the status of the monitored values to the base unit. Depending on the
implemented safety circuit, the values may be transferred from the base unit to an output
on the control system, for example. Proximity switches are used to record the values.
The configuration of the motion monitoring module is described in detail in the PNOZmulti
Configurator's online help.
The relay conforms to the following safety criteria:
}
The circuit is redundant with builtin selfmonitoring.
}
The safety function remains effective in the case of a component failure.
4.2
Block diagram
X4
A12 B12 S12 GND
X12
Mini-IO
4.3
Monitoring functions
Safe speed monitoring
The "Safe speed monitoring" function (SSM) monitors whether the current speed exceeds a
limit value.
If the configured limit value is exceeded, the output switches off. As soon as the value falls
below the limit value (plus hysteresis), the output switches off again.
8 limit values can be configured per axis in the PNOZmulti Configurator.
A tolerance range may also be set for the limit values used to monitor the speed. This toler
ance range modifies the set limit values. As a result, oneoff or periodic overshoots that ex
ceed the limit values can be tolerated.
The following values can be configured for the tolerance range: