Operation, Messages, Display elements – Pilz PNOZ mo4p 4n/o User Manual
Page 23: Display elements for device diagnostics, 7operation, 1 messages, 1 display elements

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-1
7.1
Messages
7
Operation
7
7000
Operation
Operation
7-
7.1
Messages
7100
Messages
7-
Betrieb_Meldungen_allgemein_BA
When the supply voltage is switched on, the PNOZmulti safety system
copies the configuration from the chip card.
The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up
on the base unit.
Betrieb_Meldungen_Relaisausgangsmod_BA
The PNOZmulti safety system is ready for operation when the "POWER"
and "RUN" LEDs on the base unit are lit continuously.
7.1.1
Display elements
Display elements
7-
Anzeige Legende 3x
Legend:
7.1.1.1
Display elements for device diagnostics
Display elements for device diagnostics
7-
Betrieb_Anzeige_Relaisausgangsmodul_BA
LED on
LED flashes
LED off
Basic
Relay output
module
Errors
Input Ix
RUN
DIAG
FAU
L
T
IFAULT
OFAULT
CI
CO
FAU
L
T
IN/OUT
External error on the output, e.g. defective feedback
loop
Internal error on the expansion module