Unit structure
2
Overview
2
2000
Overview
Overview
2-
2.1
Unit structure
2100
Unit structure
2-
2.1.1
Scope of delivery
Scope of delivery
2-
Lieferumfang_Brck_774639_modul_BA
`
Expansion module PNOZ mo5p
`
Jumper 774 639
2.1.2
Unit features
Unit features
2-
Geraetemerkmale_Zusatz BA Einleitung
The product has the following features:
Gertemerkmale PNOZ mo5p
`
Can be configured in the PNOZmulti Configurator
`
Positive-guided relay outputs, diverse:
4 safety outputs
Depending on the application, up to PL e of EN ISO 13849-1 and up
to SIL CL 3 of EN IEC 62061
`
Suitable for controlling the safety valves on a burner in accordance
with EN 50156
`
Status indicators
`
Plug-in connection terminals (either cage clamp terminal or screw ter-
minal)
`
Max. 8 expansion modules and one fieldbus module can be connect-
ed to a base unit. A max. 6 of these may be the expansion modules
PNOZ mo5p, PNOZ mo4p, PNOZ mo2p and PNOZ mo1p.