Automation Thruster Control

Module

Part Number - 110- 4206

This optional module enables the iQ system to control a
Dukane iQ thruster. The module is illustrated in Figure
10-14. Check your thruster operator’s manual for cable
connection information.
J5 is the HD-26 pin basic thruster connector and J6 is a
DB-9 abort switch connector. Figures 10-15 and 10-16
identify pin numbers for J6 and J5, respectively.
The Automation Thruster Control Input (J2 pin 9) is used
to control the up and down movement of the thruster.
If this input is deactivated (default), the thruster will
remain in the up position. When the input is activated,

NOTE

It is the responsibility of the machine
builder to ensure that all appropriate
safety regulations are met when using
the Thruster Control Module in an auto-
mated system. A light curtain or similar
safety guarding should be used to prevent
operator injury.

Figure 10-14

Automation Thruster Control Module

Pin No.

Input/Output

Function

Signal Types

1

Not Used

2

Not Used

3

Input

Hardware Abort Power In

Normally closed emergency switch contact

4

Input

Software Abort

Normally open dry contact switch closure to ground

5

Press Inhibit (Gnd)

Safety signal

6

Not Used

7

Ground

Ground

Internal ground

8

Not Used

9

Output

Hardware Abort Power Out

Normally closed emergency switch contact

Table 10 - V

Abort Connector Pinout (J6)

LINE VOLTAGE:
200-240 Vac
50/60Hz, 10A

PE

BASIC THRUSTER

U/S

I

0

J2

J1

J4

J3

ABORT

J5

J6

Figure 10-15

DB-9 Connector with Pin Locations (J6)

Figure 10-16HD-26 Connector with Pin Locations (J5)

1

5

6

9

1

9

10

19

26

18

the thruster will descend to the down position at a speed
that is determined by the pressure regulator setting on the
front of the thruster.