Dukane Manual Part No. 403-574-01
AC Power Requirements
The AC input power requirements depend on the frequency and output power rating of the generator.
Table 11-II below, lists both the AC requirements (maximum current drawn before overload) and the AC
outlet service rating for each model.
Operating
Frequency
Generator
Model Number
Overload
Power
Ratings
(Watts)
Input AC Power Requirements
Nominal AC Volt
@ Maximum RMS Current
North America/
Japan
AC Outlet Rating
15kHz
15XX360-2X-XX
3600
200-240V 50/60 Hz @ 25 Amps
30 Amps
15kHz
15XX480-2X-XX
4800
200-240V 50/60 Hz @ 30 Amps
20kHz
20XX120-1X-XX
1200
100-120V 50/60 Hz @ 15 Amps
15 Amps
20kHz
20XX120-2X-XX
1200
200-240V 50/60 Hz @ 8 Amps
20kHz
20XX180-2X-XX
1800
200-240V 50/60 Hz @ 12 Amps
20kHz
20XX240-2X-XX
2400
200-240V 50/60 Hz @ 15 Amps
20kHz
20XX360-2X-XX
3600
200-240V 50/60 Hz @ 25 Amps
30 Amps
20kHz
20XX480-2X-XX
4800
200-240V 50/60 Hz @ 30 Amps
30kHz
30XX090-1X-XX
900
100-120V 50/60 Hz @ 8 Amps
15 Amps
30kHz
30XX090-2X-XX
900
200-240V 50/60 Hz @ 8 Amps
30kHz
30XX120-1X-XX
1200
100-120V 50/60 Hz @ 15 Amps
30kHz
30XX120-2X-XX
1200
200-240V 50/60 Hz @ 8 Amps
30kHz
30XX180-2X-XX
1800
200-240V 50/60 Hz @ 12 Amps
40kHz
40XX060-1X-XX
600
100-120V 50/60 Hz @ 8 Amps
40kHz
40XX060-2X-XX
600
200-240V 50/60 Hz @ 5 Amps
40kHz
40XX090-1X-XX
900
100-120V 50/60 Hz @ 15 Amps
40kHz
40XX090-2X-XX
900
200-240V 50/60 Hz @ 8 Amps
40kHz
40XX120-1X-XX
1200
100-120V 50/60 Hz @ 15 Amps
40kHz
40XX120-2X-XX
1200
200-240V 50/60 Hz @ 8 Amps
NOTES:
An X used above in the Model Numbers is a “wildcard” character meaning any valid character code combination.
Maximum line current requirement is specified at the minimum nominal AC line voltage and the rated power level.
Models rated for 200-240V nominal AC line voltage include an IEC power inlet to attach an international IEC (type)
power cord. (The 3600W and 4800W models include a 30A fixed power cord.)
A power cord with a domestic three wire grounding plug is included with each standard system (NEMA 6-15P).
Models rated for 200-240V nominal AC line are fully CE compliant for use in Europe or any other country in the
world.
Models rated for 200-240V nominal AC line require a 16 Amp or 30 Amp grounded AC outlet rating, outside of North
America/Japan.
Models rated for 100-120V nominal AC line are for use in North America or Japan and include a 15 A fixed power
cord.
The fixed power cord includes a three-wire grounding plug (NEMA 5-15P configuration). These models are fully FCC
compliant, but are not usable in European countries and therefore are not CE certified.
Table 11- II