Page  7 

iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Dukane Manual Part No. 403-574-01

Optional MPC Interface Connections

Complete Steps 1 - 4 of the basic connections as de-
scribed on Pages 19-20. These involve:

Grounding (optional),

Ultrasound Output,

System Control Inputs/Status Outputs, and

AC Line Input.

Figure 10 - 5 Generator Rear View - Optional MPC Model

Option Panel Modules

A single optional module can be installed in the iQ gener-

ator’s Option Module Panel. See

A

in Figure 10 - 4 where

the option panel is set up for a Remote Control Module.

Multi- Probe Control
(MPC) Interface Option
Part Number - 110- 4251

The iQ generator can be configured with an optional MPC
Interface circuit board that powers and controls an external
MPC multi- probe control module. This external module,
(that can be ordered with a minimum of two probe controls
up to a maximum of 16 probe controls), must be purchased

In addition to completing these first four Steps, com-
plete Steps 5 and 6 to wire the MPC Control Inputs/
Status Outputs as described below.

Details about the various system connectors and their
pin assignments are covered below.

Step 5. MPC I/O - MPC control/input signals and sta-

tus output signals are carried in the I/O cables
that should already be connected - See Inputs
(J2) and Outputs (J3) in Figure 10-5.

Step 6. MPC INTERFACE - Attach one end of the

MPC Interface cable (Dukane # 200-1408-XX)
to the MPC Interface connector on the iQ gen-
erator panel -

MPC INTERFACE

in Figure 10-5.

Connect the other end of the cable to the MPC
INTERFACE connector on the right rear of the
MPC module.

NOTE

The MPC Interface cable is a separate line
item on the iQ generator system order. The
-XX at the end of the cable number speci-
fies cable length. This will vary depending
on your MPC installation.

See NOTE on
Page 77 .

LINE VOLTAGE:
200-240 Vac
50/60Hz, 10A

PE

MPC INTERFACE

U/S

I

0

J2

J1

J4

J3

Ultrasound Connector

MPC Interface

AC Breaker Switch

Grounding Stud

Inputs

Outputs

See NOTE on the
MPC cable above.