beautypg.com

Control keys, Keys left of the display, Caution – Dukane ULTRASONIC GENERATOR/POWER SUPPLY LS 403-574-01 User Manual

Page 44: Iq series

background image

Page  3 

iQ Series

,

Ultrasonic Generator/Power Supply LS User’s Manual

Dukane Manual Part No. 403-574-01

Control Keys

Keys Left of the Display

INFO
After the primary weld method has been chosen, you
can press the INFO key to go directly to the “Hot Key”
screen where frequently used menus can be accessed. In
the screens shown here, Energy is the weld method.

Use the up and down navigation keys,
to move the selection indicators,

,

to the desired selection. Press ENTER to proceed.

ON/OFF Line
The ON/OFF LINE key is used to deactivate the
ultrasonic signal. For example, select OFFLINE during
your process setup or to cycle the assembly equipment
without ultrasound activated.

Keys - Right of Display

Keys - Left of Display

LOAD

80

60

100

OVER

40

0

20

SYSTEM POWER OUTPUT LEVEL

SYSTEM OPERATING MODE

ON

LINE

OFF

LINE

POWER

TEST

# 1 PART COUNT 125
WELD TIME 0.080 S
POWER 1050 W
ENERGY 350 J

INF

O

O

N

/O

FF

LIN

E

TE

ST

C

AN

CE

L

ENT

ER

Figure 5 - 2 Front Panel Control Detail

Navigation Keys (4)

WELD ENERGY HOTKEY
AMPLITUDE
PROCESS SETUP
SYSTEM INFO

Weld Method - Time, Energy, Power,
- programmed by the user.
Time is the default method.

Screen shown in Operate Mode.

Screen shown in Setup Mode.

WELD ENERGY HOTKEY
AMPLITUDE
OPERATE
SYSTEM INFO

SYSTEM INFO will give
the software version,
model number.

If a transducer is not connected to
the ultrasound output connector,
the system should be set to the
OFFLINE mode. Do not activate

the ultrasound output without a
transducer connected. Make sure
that the stack is properly assembled
before it is connected to the system.
The horn should never come in
direct contact with a metal fixture
or anvil with ultrasound activated.

CAUTION