System Parameter Settings
Overview
This section provides the default system settings
programmed at the factory. Some of these system
parameter settings are dependent on the nominal
system operating frequency while other parameters are
independent of the frequency. The default settings should
work with over 90% of the ultrasonic loads and welding
applications that might be encountered. In some cases,
adjusting the system setup parameters might enable the
system to drive difficult or unusual loads, which would
not be possible with the standard system settings.
In addition to the default system parameter settings, a list
of user-adjustable settings is included.
Table 5 - I Default Frequency Dependent Settings
Default System Parameter Settings
Default Frequency Dependent Settings
Setting Description
15kHz
20kHz
30kHz
40kHz
Free Running Frequency Setting (Hz)
15,000
19,900
30,000
40,000
Upper Frequency Limit Setting (Hz)
15,400
20,400
30,500
40,500
Lower Frequency Limit Setting (Hz)
14,600
19,400
29,500
39,500
Ramp-up Time Setting (sec.)
0.250
0.
150
0
.100
0
.050
Phase Delay Setting (degrees)
0
°
0°
0°
0°
Default Frequency Independent Settings
Setting Description
Default Setting for All Frequencies
Amplitude Setting for Weld and Test (Percent)
100% (maximum user adjustment limit)
Output Activation Duration Process Status
Maintained (activates until next weld cycle starts)
Cycle Start Input Delay Time
Solid State (0.0msec. delay time)
Programmable Status Output #1 Default Assignment
OVERTEMP Status (J3 Pin 4 System Output)
Programmable Status Output #2 Default Assignment
Hold Status (J3 Pin 5 System Output)
NOTE
An ultrasonic stack will not operate if the
mechanical resonance is outside of the
frequency limits.
Table 5 - II Default Frequency Independent Settings