Section 7 – System Operational Testing
Dukane Manual Part No. 403-574-01
Probe Operation
1. If the generator is not online, press the ON/OFFLINE
mode key, labeled
C
in Figure 7-6. The System Op-
erating Mode ONLINE indicator (
G
in Figure 7-5)
will be green.
2. Hand Probe – Apply the probe tip to the components
to be ultrasonically joined, and press the hand probe’s
activation switch.
Automation System – Activate the automation system
program to trigger the generator. This will move the
probe tip in contact with the components to be ultra-
sonically joined, and run a welding cycle.
3. Hand Probe – The programmed welding time or energy
will be processed, and then the ultrasound will be shut
off.
Automation System – The programmed weld time will
be processed, and then the ultrasound will shut off.
NOTE
Neither a hand probe or an automa-
tion system can trigger the generator
to produce an ultrasound output if the
generator is OFFLINE.
Stopping the Ultrasound
Output
Set mode key
C
to OFFLINE. Ultrasound will
deactivate.
Figure 7 - 6 Stop Ultrasound Output
C
LOAD
80
60
100
OVER
40
0
20
SYSTEM POWER OUTPUT LEVEL
SYSTEM OPERATING MODE
LOAD
80
60
100
OVER
40
0
20
SYSTEM POWER OUTPUT LEVEL
SYSTEM OPERATING MODE
ON
LINE
OFF
LINE
POWER
TEST
# 1 PART COUNT 125
WELD TIME 0.080 S
POWER 1050 W
ENERGY 350 J
OFF
LINE
# 1 PART COUNT 125
WELD TIME 0.080 S
POWER 1050 W
ENERGY 350 J
INF
O
O
N
/O
FF
LIN
E
TE
ST
C
AN
CE
L
ENT
ER
System with a User-supplied
Emergency Stop Switch
Press the emergency (E-Stop) switch, and the ultrasound
signal will deactivate. - This applies only if Auto Stop
is wired to end user E-Stop circuits, AND Auto Stop is
enabled.