beautypg.com

I/o panel options, Single connector system i/o panel – Dukane ULTRASONIC GENERATOR/POWER SUPPLY LS 403-574-01 User Manual

Page 81

background image

Page  75

Section 10 - Options

Dukane Manual Part No. 403-574-01

I/O Panel Options

Single Connector System I/O Panel

See

B

in Figure 10-4 where the I/O panel is set up for the

single I/O connector, a HD15F type. The generator label
for this connector is, SYSTEM INPUTS/OUTPUTS

.

Another label identifies the connector as J12.

The I/O panel can be customized with multiple types of
connectors such as the single HD15F, terminal blocks,
etc. Contact your local sales representative for more
details

.

Table 10-I shows an example of a customized option:
Pins/Signals duplicate a Dukane DPC-I generator.

5 4 3 2 1

5 4 3 2 1

15 14 13 12 11

15 14 13 12 11

6

6

10

10

Figure 10 - 3 HD15F for System Inputs/Outputs
Connector

Figure 10- 4 Option Panel and I/O Panel
(NOTE: Shown are the Option panel with Remote
Control Module, and the I/O panel with single I/O
connector.)

Option Panel

I/O Panel

B

Pin

Signal Name

Signal Description

1

+22VDC

Current limited to 250mA maximum

2

Ground

22VDC Return (chassis ground)

3

Ground

Status Outputs/Driver/Monitor Return

4

Status Driver

Status Driver Output (1 Amp max.)

5

Ultrasound Active Status

Ultrasound Status Output (Active Low)

6

Overload Fault Status

Overload Fault Output (Active Low)

7

Isolated Operate Input Common

Isolated Operate Input Common (7 & 8) JU726

8

Operate Input

Sw Closure Operate Inut (2 & 8) JU724/725

9

Over Temperature Fault

Over Temperature Fault Output (Active Low)

10

System Fault

System Fault Output (Active Low)

11

Not Used

Reserved - HPPI Signal

12

Amplitude Setting

Amplitude Setting Monitor (10.0V = 100%)

13

Power Signal Common

Power Signal Common

14

Power Signal

Power Signal Monitor Output (1mV = 1 Watt)

15

Loop Fault

Current Loop Fault Output (Active Low)

Table 10- I HD15F Example of Customized System Inputs/Outputs Connector Signals

A