SpectraCal Lumagen Radiance User Manual
Page 4

3528 Bagley Ave. N. Seattle, WA 98103 USA
Corporate: +1 206 420 7514 | Tech Support: +1 206 457 8949 |
CalMAN Grayscale and CMS Calibration:
To connect a Radiance for grayscale calibration and standard CMS primary/secondary color calibration:
1. In the Radiance menu, set the 3D Color Gamut Options to Disabled and 8 Points.
o Menu > Output > CMS’s > CMSx > Color Gamut > Options > Enabled; No
o Menu > Output > CMS’s > CMSx > Color Gamut > Options > Points; 8
2. In CalMAN, load the "SI Advanced" workflow.
3. On the CalMAN Settings tab (gear icon), under Workflow Basic Options, select Video (16-235)
[SMPTE legal].
4. Proceed through each step of the workflow in the normal fashion, using the following notes for
guidance on the indicated workflow pages.
5. On the Hardware Connect page, click the Find Source button, select “Lumagen – Radiance
series,” then click Connect.
6. On the Hardware Connect page, click the Find Processor/Display button, select "Lumagen –
Radiance CMS,” then click Connect.
7. On the Dynamic Range page, adjust the display’s black level/Brightness control to 16.
8. Skip the Grayscale - 2pt page (no advantage when doing the following multipoint AutoCal).
9. On the Grayscale/Gamma page, click the AutoCal button and wait for the AutoCal process to
complete.
10. On the CMS Calibration page, click the AutoCal button and wait for the AutoCal process to
complete.
DONE – Radiance Grayscale and CMS calibration is complete.