Palsun® technical guide – Palram PALSU User Manual
Page 15

PALSUN® Technical Guide
15
PALSUN® Recommended Panel width - 4 sides clamped (Continued)
Thickness
Load
kg/m2
Length / Width Ratio (b/a)
Ratio 1:1
Ratio 1.25:1
Ratio 1.5:1
Ratio 1.75:1
Ratio 2:1
8mm
50
1975
1750
1625
1590
1575
75
1725
1525
1425
1390
1375
100
1565
1390
1300
1270
1250
125
1455
1290
1210
1180
1160
150
1375
1210
1140
1110
1090
175
1300
1150
1080
1050
1035
200
1250
1100
1035
1005
990
10mm
50
2050
2050
2050
1990
1960
75
2050
1910
1795
1740
1715
100
1960
1735
1630
1580
1555
125
1820
1610
1515
1465
1445
150
1710
1515
1425
1380
1360
175
1625
1440
1355
1310
1290
200
1555
1375
1295
1255
1235
12mm
50
2050
2050
2050
2050
2050
75
2050
2050
2050
2050
2050
100
2050
2050
1955
1895
1870
125
2050
1935
1815
1760
1735
150
2050
1820
1710
1655
1630
175
1950
1730
1625
1575
1550
200
1865
1655
1555
1505
1480
14mm
50
2050
2050
2050
2050
2050
75
2050
2050
2050
2050
2050
100
2050
2050
2050
2050
2050
125
2050
2050
2050
2050
2025
150
2050
2050
2000
1930
1900
175
2050
2000
1890
1835
1810
200
2050
1925
1810
1755
1730
15mm
50
2050
2050
2050
2050
2050
75
2050
2050
2050
2050
2050
100
2050
2050
2050
2050
2050
125
2050
2050
2050
2050
2050
150
2050
2050
2050
2050
2025
175
2050
2050
2025
1950
1925
200
2050
2050
1925
1875
1850
18mm
50
2050
2050
2050
2050
2050
75
2050
2050
2050
2050
2050
100
2050
2050
2050
2050
2050
125
2050
2050
2050
2050
2050
150
2050
2050
2050
2050
2050
175
2050
2050
2050
2050
2050
200
2050
2050
2050
2050
2050
* For wind load data in N/m2 units, multiply value by 10 (e.g. 40 kg/m2 = 400 N/m2).
Notes:
1. For 2 sides clamped installation please refer to the ratio 2:1 column.
2. The table is referring to various ratios of Length (b) and width (a) and valid for both Snow and wind load.
3. The table is referring to 4 sides clamped, flat installed Palsun panels.
4. Bedding depth shall be minimum 20mm.
5. The values are calculated according to deflection criterion of L/20 of the short span.
6. The table is not referring to self-weight deflections which might cause aesthetic issues.
7. The table is not referring to the sheet flexibility when vertically installed.
8. The data in the table refer to the short dimension, a.