Determination of Required Sheet Dimensions
The information below is presented to assist in ordering the required dimensions.
Determination of Sheet Size
Due to thermal expansion, PALSUN & PALTUF sheets have to be cut
accurately at predetermined lengths smaller than the dimensions
of the frame. At the end of the frame, clearance must be left for
expansion. The following tables and diagram help calculate the
required sheet dimensions. In addition, there is a table showing
the expansion clearance necessary for various sizes of PALSUN &
PALTUF sheets.
Determination of Thickness
In order to determine the required thickness, the following table
lists the sheet thickness required for a given wind load and width
(at the narrow side of the sheet).
PALSUN® Recommended Panel width
Wind/Snow Load Chart for Flat 4 Sides Clamped, Single Panel, Single Span
Thickness
Load
(kg/m2)
Length / Width Ratio (b/a)
Ratio 1:1
Ratio 1.25:1
Ratio 1.5:1
Ratio 1.75:1
Ratio 2:1
4mm
50
985
875
820
795
785
75
860
765
715
695
685
100
780
695
650
630
620
125
725
645
605
585
575
150
685
605
570
550
540
175
650
575
540
525
515
200
620
550
515
500
490
5mm
50
1235
1090
1025
995
980
75
1075
955
895
870
855
100
980
865
815
790
775
125
910
805
755
730
720
150
855
755
710
690
680
175
810
720
675
655
645
200
775
685
645
625
615
6mm
50
1450
1300
1225
1200
1175
75
1300
1150
1075
1050
1025
100
1175
1025
975
950
925
125
1090
965
910
885
865
150
1025
910
850
830
815
175
975
865
810
790
775
200
925
825
775
755
740
A
A
a - width
B
B
A-A
B-B
b - length