Coe BG2 Interface

The connection to a Coe BG2 Electronic Feed is

as follows:

Table 2.2

Coe BG2 Connections

Link PN 106739

OmniLink
Feed Port

Function /
Color

Coe COM2
port

Pin 1
(GND)

Ground
(WHITE)

Pin 7

Pin 2
(RXD)

Receive data
from feed
(BLACK)

Pin 2

Pin 3
(TXD)

Transmit data to
feed (RED)

Pin 3

Notes:

‚

The COM2 port is located on the Coe operator
interface terminal

‚

the COM2 port requires that pins 6, 8, and 20
(of COM2) be connected together.

‚

The feed communications settings (as set in the
Coe operator terminal) should be 9600 Baud, 7
data bits, Odd parity, 1 stop bit.

‚

The feed will not communicate when in an error
condition or when in a parameter entry screen
(setting length, speed, acceleration, etc).