OmniLink 5000 Feed Manual
December 13, 1999
2.3
Manual Rev 2.3
2.4
Coe BG2 Interface
The connection to a Coe BG2 Electronic Feed is
as follows:
Table 2.2
Coe BG2 Connections
Link PN 106739
OmniLink
Feed Port
Function /
Color
Coe COM2
port
Pin 1
(GND)
Ground
(WHITE)
Pin 7
Pin 2
(RXD)
Receive data
from feed
(BLACK)
Pin 2
Pin 3
(TXD)
Transmit data to
feed (RED)
Pin 3
Notes:
The COM2 port is located on the Coe operator
interface terminal
the COM2 port requires that pins 6, 8, and 20
(of COM2) be connected together.
The feed communications settings (as set in the
Coe operator terminal) should be 9600 Baud, 7
data bits, Odd parity, 1 stop bit.
The feed will not communicate when in an error
condition or when in a parameter entry screen
(setting length, speed, acceleration, etc).