beautypg.com

Dsp configuration – Lab.gruppen IPD 2400 User Manual

Page 7

background image

7

DSP configuration

Default configuration

IPD Series amplifiers are shipped with default DSP settings that allow

immediate use in many common applications with no need for further

DSP configuration. The default mode is suited for use with the stereo

program into full range loudspeakers. The main signal routing and

parameter settings are as follows:

Input mixer:

Analog 1 and AES1 are routed to Ch. 1

Analog 2 and AES 2 are routed to Ch. 2

AES3 to analog failover is OFF

Output Mute: Muted

Mode: Stereo

Output EQ: Flat

Input levels: 0 dB

Delay: Off

Input EQ: Flat

Crossover: Off

Output levels: 0 dB

Fig 2

Analog 1

Analog 2

AES 1

AES 2

Input 1

Levels

Input 1

EQ

Input 1

delay

Output 1

Levels

Output 1

EQ

IDEEA

Amplifier

Output 1

Delay

Clip Limiter

Clip Limiter

Rail Sense Limiter

SCVPL

X-Over

Input 2

Levels

Input 2

EQ

Input 2

delay

Output 2

Levels

Output 2

EQ

IDEEA

Amplifier

PSU

Output 2

Delay

SCVPL

X-Over

Input

Mixer

Fig 3

Presets

Load

Store

Meters

Mixer

I/O Meters

Input 1 & 2

Gain

Delay

Link

Imput

Mixer

Device Config

Mode

Lock

LCD

Brightness

Device

Name

Device Info

Serial

Number

Temperature

Reading

Mac

Address

IP Address

H/W Version

Software

Version

Output 1 & 2

Gain

Delay

Link

Limiter

Threshold

X-Over

LPF

HPF

Phase

Norm/

Invert

Enable

Type

Freq

Gain

Q / BW

PEQ 1-10

Enable

Type

Freq

Gain

Q / BW

PEQ 1-10

Signal flow block diagram

The block diagram below shows the signal flow from inputs to outputs.

*see fig 2

Front panel configuration

Input mixing and routing, as well as all DSP parameters, may be

configured using the Menu and Back buttons and the Adjust/Set rotary

encoder. The following menu tree is keyed to points in the signal flow

block in fig 2.

*see fig 3

This manual is related to the following products: