26 x1 mf – HITEC X1 MF: AC/DC, 80-Watt, Multi-Function, Charger User Manual
Page 27

˚
3 seconds
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
Press
Dial
26
X1 MF
TVC=YOUR RISK!
 4.20V
TEMPERATURE
CUT-OFF 50C
SAVE PROGRAM
 ENTER
BATT MEMORY [1]
LiPo 7.4V(2S)
BATT MEMORY [1]
C:4.3A D:2.2A
PROGRAM SELECT
 BATT MEMORY
ENTER CHARGER
LOAD....
Set the process termination voltage. Range: 4.18V - 
4.30V. CAUTION: be sure to set/verify the correct 
end voltage of the type of cell you are charging. 
Over charging batteries can result in fire or 
explosion!
If you are using the optional external Temperature 
Sensor, set the temperature cutoff. If you are not 
using the Temperature Sensor, leave this setting 
as-is.
Save the program entry by pressing and holding the 
dial for 3 seconds.
Once saved, the display will return to the newly 
saved programs entry in the saved program list.
To recall a saved program, press Mode/Stop, scroll 
to the Program Select Batt Memory screen and 
press the dial. 
Rotate the dial through the saved memory slots until 
you find the memory you are trying to activate. 
Once located, press and hold the dial for 3 seconds.
This screen indicates that the memory you have 
selected is being loaded and activated.