beautypg.com

Installation, Rear flue, Side flue – Glow-worm Flue User Manual

Page 9

background image

0020095198_02 - 06/11 - Glow-worm

INSTALLATION

- 9 -

3 Top Horizontal Telescopic flue Kit

Ø60/100 - Pt. no. a2043600

Check the contents of your kit.

3.1

flue length and Terminal position

Refer to your Installation instructions supplied with the

appliance to confirm the flue length available and location of the

flue terminal, then proceed as follows:

• With the flue elbow temporarily fitted, measure the distance

from the external wall to the elbow.

noTe: * If fitting the sealing collar, add a further 12mm to the

overall length ‘Y’, see diagrams below.

• Set the flue ducts to the required length ‘Y’. If the

measurement ‘Y’ exceeds the telescopic flue length, then the

appropriate length of extension pipe will be required.

15610

ReaR flUe

*

‘Y’

1561

1

sIDe flUe

*

‘Y’

DO NOT cut the telescopic flue, if the flue length

cannot be achieved, the standard flue or extensions

should be used.

If desirable the flue can project to a maximum of 600mm

beyond the outside wall face.