INSTALLATION

- 25 -

1.

2.

3.

4.

5.

7.

6.

7.5

fitting elbows

The elbows must be correctly aligned to avoid undue

stress on the joints and risk of leakage.

• The elbow fitted to the top of the boiler (1) should be twisted

by 3° to ensure that the second 87° elbow (2) exits the wall

perpendicular.

7.6

flue Terminal assembly fitting

• Push the flue terminal assembly into the wall, externally or

internally, until the end of the assembly protrudes a short

way from the inside face of the wall. This will enable the

assembly to be drawn back into the flue elbow on top of the

flue adapter.

• Fit the internal trim plate.

• Secure the flue elbow with the securing collar in position on

top of the vertical flue adapter.

• Ensuring correct alignment of the flue terminal assembly to

the flue elbow and secure with the securing collar.

• Mark through two of the pre drilled holes in the securing

collars.

• Drill 3mm diameter holes, take care not to pierce the inner

flue duct.

• Secure the securing collars to the air duct, see inset 1.

• Make good the external wall face and fit the external trim

ring.

noTe: The air inlet must protrude completely beyond the face

of the external wall and the external trim ring.

On completion of flue installation, continue with the appliance

installation, referring to the appropriate section of the appliance

installation instructions supplied.

SECURING

COLLAR

SECURING

COLLAR

TERMINAL

ASSEMBLY

MAXIMUM

220mm

SECURING

SCREW

(4 OFF)

SECURING

SCREW

(2 OFF)

INSET 1.

VERTICAL

FLUE

ADAPTER

INSET 2.

EXTERNAL

TRIM RING

INTERNAL

TRIM

PLATE

AIR INLET

7.7

Horizontal flue Roof Termination

Order the flue flashing from from Ubbink, Northants, Telephone

01280 700211.

• Follow the previous instructions and the diagram below, to

prepare the flue and follow the instructions supplied with the

flashing.

82 - 90