Installation, A) (b) (c) (d) (e) (f) (g) (h), 6 accessories – Glow-worm Flue User Manual
Page 16: 2 installation, Check the contents of your kit
0020095198_02 - 06/11 - Glow-worm
INSTALLATION
- 16 -
6 accessories
6.1
Deflector flue Terminal Kit Ø60/100
Check the contents of your kit.
Part no. 0020060582 - black
Part no. 0020060583 - White
Installation Instructions
www.glow-worm.co.uk
Deflector flue terminal kit
Part No.
A200*****
Because of our const
ant endeavour for im
provement, d
etails may vary
slightly from
those show
n in these inst
ructions.
Glow-wo
rm, Nottingham Road, B
elper, Derbyshire. DE56 1JT
0020068279-02 04 .08
General/S
ales enqu
iries:
Tel: (0177
3) 828100
Fax: (01
773) 8280
70
Installation refer to
diagram 2.
The terminal
kit fits onto the telescopic and sta
ndard
horizont
al flue, see diagram 1 for
conten
ts.
NOTE:
The deflector
terminal kit can
be fitted after the boiler
and flue have been
installed.
Remove the rubber collar (a).
Use a 8mm
. flat scr
ewdriver to bend catches inwar
ds (b).
Remove the
flue terminal
and flue duct
(c).
Remove the
flue pi
pe from
the flue term
inal by twisting them
against each other (d
).
Push the fl
ue duct into the deflector fl
ue term
inal.
NOTE:
the catch on top (i
nside) the term
inal mus
t lock firmly
into the notch o
n top of th
e flue duc
t (e).
Fit the rubber
collar
suppl
ied with the kit
(f).
Push the fl
ue duct an
d term
inal into the ai
r duct
make sure
the seals
fit tight
ly.
The defl
ector part
of the deflector
flue term
inal can be
rotated 45
o
to the left or right
if requir
ed (g).
NOTE:
Do not fit the deflector flue
terminal with t
he deflector
positioned
downwards.
If the boiler has not been fitted, contin
ue as described in the
installa
tion, servicing and user ins
tructions supplied with t
he
boiler.
To rem
ove the deflector flue
terminal from
the air duct pull
the locking strap down (h), this will r
elease the two
side
locking pos
itions (f).
14697
14696
Diagram
1
Diagram 2
For Us
e Wit
h
Glow
-worm High Efficiency
Condensing Combination
Boilers
(a)
(b)
(c)
(d)
(e)
(g)
(h)
(f)
The Deflector Flue Terminal kit will fit either the telescopic
or standard horizontal flue systems and is designed to be
rotated 45º from the top centre, directing the plume away from
openings, people, cars, windows etc.
It can be fitted after the appliance and flue have been installed.
Should the deflector terminal be positioned under a soffit or
horizontal surface, it is allowed to project the flue 600mm from
the wall, to allow the discharge of flue gases produced into free
air.
Do not fit the deflector flue terminal with the deflector
positioned downwards.
6.2
Installation
(a) If previously fitted, remove the rubber collar.
(b) Using a 8mm. flat screwdriver to release the catch.
(c) Withdraw the flue terminal and pipe from the duct.
(d) Remove the flue pipe from the terminal, twist and pull,
discard the terminal.
(e) Locate the “notch” on the pipe, align with the “catch” on the
deflector terminal and push the pipe into position, ensuring that
the engagement is secure.
(f) Fit the rubber collar
(g) Rotate the deflector to suit your requirements.
(h) Releasing Strap.
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
Push the flue pipe and terminal into the air duct, make sure the
seals fit tightly.
To remove deflector flue terminal from the air duct pull locking
strap down (h), this will release both side locking positions (f).