Installation, Rear flue, Side flue – Glow-worm Flue User Manual
Page 11
![background image](/manuals/736780/11/background.png)
0020095198_02 - 06/11 - Glow-worm
INSTALLATION
- 11 -
4 Top Horizontal standard flue Kit
Ø60/100 - Pt. no. a2043400
Check the contents of your kit.
4.1
flue length and Terminal position
Refer to your Installation instructions supplied with the
appliance to confirm the flue length available and location of the
flue terminal, then proceed as follows:
• With the flue elbow temporarily fitted, measure the distance
from the external wall to the elbow.
noTe: * If fitting the sealing collar, add a further 12mm to the
overall length ‘Y’, see diagrams below.
• Set the flue ducts to the required length ‘Y’. If the
measurement ‘Y’ exceeds the telescopic flue length, then the
appropriate length of extension pipe will be required.
15610
ReaR flUe
*
‘Y’
1561
1
sIDe flUe
*
‘Y’
4.2
flue cutting
• Separate the flue duct from the terminal by twisting to
release the terminal catch.
The flue duct cutting length is (L + 11mm), see diagram.
noTe: If fitting the sealing collar, add a further 12mm to the
overall length. However if desirable the flue can project to a
maximum of 600mm beyond the outside wall face.