INSTALLATION
- 10 -
• Align the air duct seams.
• Mark and drill a 3mm hole in the air duct, taking care not to
pierce the inner flue duct.
• Secure the joint with the screws and tape provided.
• If required, fit the sealing collar onto the locating ring of the
flue terminal.
• Remove the flue elbow.
• Push the flue assembly into the wall, until the end of the
assembly protrudes a short way from the inside face of the
wall. This will enable the internal trim ring (if required) to be
positioned and allow the flue assembly to be drawn back up
to the flue elbow.
• Secure the flue elbow in position on top of the appliance with
four screws supplied.
• Fit the flue assembly to the elbow.
• Fit the securing collar into position.
• Ensuring correct alignment of the air duct seam, mark
through two of the pre drilled holes in the securing collar.
• Remove securing collar and drill two 3mm diameter holes
one in the elbow and one in the air duct, take care not to
pierce the inner flue duct. Secure collar and air duct with
screws provided.
• Slide the internal trim ring back against the wall, securing in
place with a small amount of sealant if required.
• Check that the outer rubber sealing collar makes an effective
seal against the wall face.
On completion of flue installation, continue with the appliance
installation, referring to the appropriate section of the appliance
installation instructions supplied.