Installation – Glow-worm Flue User Manual
Page 12
![background image](/manuals/736780/12/background.png)
0020095198_02 - 06/11 - Glow-worm
INSTALLATION
- 12 -
The air duct should be cut at the opposite end to the terminal
and the plastic flue duct MUST be cut at the opposite end to the
terminal catch.
The plastic flue duct extensions MUST be cut at the opposite
end to seal.
• Insert the flue duct into the air duct terminal assembly,
remembering to engage the catch within the terminal.
*
noTe:
If fitting sealing
collar an
additional 12mm
is required
4.3
flue fitting
• Fit the sealing collar onto the locating ring on the flue
terminal, see diagram 5.
• With the flue terminal removed, push the flue assembly into
the wall, externally or internally, until the end of the assembly
protrudes a short way from the inside face of the wall. This
will enable the internal trim ring (if required) to be positioned
and allow the flue assembly to be drawn back into the flue
elbow.
• Secure the flue elbow in position on top of the appliance with
four screws supplied.
• Fit the flue assembly to the flue elbow.
• Fit the securing collar into position.
• Ensuring correct alignment of the flue, mark through two of
the pre drilled holes in the securing collar.
• Remove securing collar and drill two 3mm diameter holes
one in the elbow and one in the air duct, take care not to
pierce the inner flue duct, secure collar with screws provided.
• Slide the internal trim ring back against the wall, securing in
place with a small amount of sealant if required.
• Check that the outer rubber sealing collar makes an effective
seal against the wall face.
noTe: If the air and flue ducts have been correctly cut to the
instructions the sealing collar should fit flush with the outside
wall.
On completion of flue installation, continue with the appliance
installation, referring to the appropriate section of the appliance
installation instructions supplied.