- 12 -

The air duct should be cut at the opposite end to the terminal

and the plastic flue duct MUST be cut at the opposite end to the

terminal catch.

The plastic flue duct extensions MUST be cut at the opposite

end to seal.

• Insert the flue duct into the air duct terminal assembly,

remembering to engage the catch within the terminal.

*

noTe:

If fitting sealing

collar an

additional 12mm

is required

4.3

flue fitting

• Fit the sealing collar onto the locating ring on the flue

terminal, see diagram 5.

• With the flue terminal removed, push the flue assembly into

the wall, externally or internally, until the end of the assembly

protrudes a short way from the inside face of the wall. This

will enable the internal trim ring (if required) to be positioned

and allow the flue assembly to be drawn back into the flue

elbow.

• Secure the flue elbow in position on top of the appliance with

four screws supplied.

• Fit the flue assembly to the flue elbow.

• Fit the securing collar into position.

• Ensuring correct alignment of the flue, mark through two of

the pre drilled holes in the securing collar.

• Remove securing collar and drill two 3mm diameter holes

one in the elbow and one in the air duct, take care not to

pierce the inner flue duct, secure collar with screws provided.

• Slide the internal trim ring back against the wall, securing in

place with a small amount of sealant if required.

• Check that the outer rubber sealing collar makes an effective

seal against the wall face.

noTe: If the air and flue ducts have been correctly cut to the

instructions the sealing collar should fit flush with the outside

wall.

On completion of flue installation, continue with the appliance

installation, referring to the appropriate section of the appliance