INSTALLATION

- 24 -

25 mm

15 mm

5 mm

CUT THIS

END ONLY

AIR DUCT

TWIST

INNER

SECURING

CATCH

FLUE

DUCT

5 mm

noTe: For assembly reasons do not shorten any air duct to a

length of less than 100mm. If necessary shorten two adjacent

extensions to achieve the overall required length.

noTe: For installations where there is insufficient movement

to allow fitting of the flue into flue outlet, a sliding sleeve is

available Part No. 0020104558. When using the sliding sleeve

both the air and flue ducts of the last extension must be

shortened by a further 85mm.

7.4

Installing the sliding sleeve

Push the sliding sleeve (1) over the cut end of the flue duct (2).

Pull back the sliding sleeve so that it engages into the socket

(3) of the boiler (4). Ensure that the sliding sleeve penetrates

the socket such that there is at least 20 mm engagement at

both ends of the sliding sleeve. Fit the air duct clamp (7) over

the air ducts (5 and 6) of the extension/terminal and boiler

outlet. Close the snap clamp.

Drill two holes 3mm diameter through the air duct clamp (7) (the

centre of the holes should be 6mm from the edge of the clamp).

Ensure that the drill does not penetrate the inner flue duct.

Screw the air duct clamp to the air duct of the sleeve using the

screws provided.

Complete the installation of the flue as detailed in these

instructions.

7.1

Top Horizontal standard flue Ø80/125

Refer to diagram 1 and check the contents of your kit.

Make sure you have all the necessary components before

proceeding with the installation.

7.2

flue length and Terminal Position

Refer to your Installation instructions supplied with the

appliance to confirm the flue length available and location of the

flue terminal, then proceed as follows:

• Secure the flue adapter in position on top of the appliance

with four screws supplied.

noTe: Make sure the nib fits into the locating slot in the

appliance casing to ensure correct orientation.

• With the flue elbow temporarily fitted, measure the distance

from the external wall to the elbow.

SIDE FLUE

*

‘Y’

• If the measurement ‘Y’ exceeds the achievable flue length,

960mm. then the appropriate length of extension pipe is

required.

7.3

extension cutting

• Separate the flue duct from the terminal by twisting to

release from the securing catch inside the air/flue duct

• When cutting, cut equal amounts off the air duct and flue

duct.

• When joining extensions leave a gap of 5mm between

each air duct this will leave a correct flue duct connection of

30mm.