Plow, Rt45 operator’s manual – Ditch Witch RT45 User Manual
Page 163

Service - 166
RT45 Operator’s Manual
500 Hour
CMW
®
Test Coolant Freeze Protection Level
With engine cool, test coolant freeze protection
level using a hydrometer or refractometer.
Recommended freeze protection level is -34°F
(-37°C). Adjust as needed.
If colder temperatures are expected, consult your
Ditch witch dealer or coolant supplier.
Use pre-dilluted coolant to maintain proper freeze
protection.
Plow
Change Plow Vibrator Oil
Change plow vibrator oil every 500 hours.
To change:
1.
Open fill (1) to vent vibrator.
2.
Drain oil at drain plug (3).
3.
Replace plug and move plow vibrator to horizontal position.
4. Add MPL at fill (1) until oil is halfway up sight glass (2).
IMPORTANT: See page 142 for information
on approved coolants.
273-423
Hot parts may
cause burns. Do not touch until cool.
To help avoid injury: Do not drain oil from
plow vibrator when hot. Let vibrator cool before
removing drain plug.
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK750/SK755 (81 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)