Rt45 operator’s manual – Ditch Witch RT45 User Manual
Page 119
Microtrenching - 120
RT45 Operator’s Manual
Setup
CMW
®
Prepare Spoils Removal
The MT12 MicroTrencher is designed to operate optimally with an 800 cfm vacuum excavator unit to
remove spoils. If vacuum excavator is not available, set up unit to operate without it.
With Vacuum Excavator
1.
Connect vacuum hose on excavator to vacuum hose on tractor.
2.
Operate vacuum unit at full speed for best results. Full vacuum flow to the microtrencher is necessary
for best spoils removal.
Without Vacuum Excavator
1.
Cap vacuum hose on tractor.
2.
Remove chute plates (1).
3.
Install spoils chutes (2).
Read operator’s manual. Know how to use all controls
before operating machine. When you see this sign
on the machine or
in the manual, read it and use caution. Your safety is at stake.
273-475
To help avoid injury: Do not operate without blade cover and chutes or
chute plates installed.
IMPORTANT: Ensure that vacuum hoses are clear, vacuum filters are clean, and separator
canister is empty prior to operation.
IMPORTANT: Note orientation of spoils
chute as indicated by decal on chute.