50 hour, Vacuum system, Fx50 operator’s manual – Ditch Witch FXT50 User Manual
Page 92
FX50 Operator’s Manual
Service - 91
50 Hour
CMW
50 Hour
Vacuum System
Check Water Pump Belt Tension
Check belt every 10 hours for correct tension,
damage or wear. Replace worn belt. Tighten as
needed. See “Adjust Water Pump Belt Tension”
on page 103.
To check
1.
Turn ignition to STOP and remove key.
2.
Apply moderate thumb pressure to belt
between pulleys.
Belt is properly tensioned when deflection is
about .2-.3” (5-8 mm).
Location
Task
Notes
Vacuum
System
Check water pump belt tension
Check fan belt tension
Check blower belt tension
Inspect cooling fan
Check blower relief valve
Check water pressure hoses
Debris Tank
Lube tank pivot pins
Vacuum
Boom
Lube boom pivot
Boom is optional equipment
j36om014w.eps