beautypg.com

Fx50 operator’s manual – Ditch Witch FXT50 User Manual

Page 89

background image

Service - 88

FX50 Operator’s Manual

10 Hour

CMW

Clean Vacuum Air Filter

Clean filter every 10 hours or as needed.

To clean filter:

1.

Remove filter from canister.

2.

Run low pressure water into inside of filter.

3.

Allow filter to dry completely before returning
to canister.

Check Spray Nozzle

Check spray nozzle every 10 hours. Ensure that
water sprays from nozzle in a fan pattern. Clean
or replace nozzle as necessary.

Drain Cyclonic Separator Canister

Drain canister at drain (2) every 10 hours or when
water is visible in sight glass (1).

NOTICE: Do not use high pressure water
to clean filter. Filter will be damaged.

IMPORTANT: Depressurize tank before
emptying cyclonic canister, cleaning filter,
clearing hoses or opening any doors.

j36om027w.eps

j36om029w.eps

1

2

j36om028w.eps

This manual is related to the following products: