Unload to another tank, Fx50 operator’s manual – Ditch Witch FXT50 User Manual
Page 65
Vacuum and Pothole - 64
FX50 Operator’s Manual
Unload to Another Tank
CMW
Unload to Another Tank
Optional reverse flow mode can be used to transfer vacuumed material to another tank or disposal site.
1.
Throttle down completely and turn off engine. Securely connect transfer hose to FX tank. Ensure drain/
outlet valve on FX tank is closed.
2.
Securely connect other end of transfer hose to offboard tank. Ensure inlet valve on offboard tank is
closed and tank is vented.
3.
Open FX tank drain/outlet valve. Material will flow into transfer hose.
4.
Open offboard tank inlet valve.
Incorrect procedures could result in death, injury, or property damage.
Learn to use equipment correctly.
To help avoid injury:
•
Keep unit in “vacuum” mode unless pressure is needed.
•
Restrain hose prior to pressurization. Unrestrained hose may cause property damage, injury or
death.
•
Do not open fitting cams or valves when tank is pressurized. Flying debris, plugs and doors can
cause injury or death.
•
Do not open tank door while tank is pressurized.
•
Do not use pressure to clear clogs in vacuum hose.
IMPORTANT: Check relief valves as shown
before each use.
j33om059h.eps